1.
Sci Rep ; 14(1): 8145, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584229

RESUMO

Photoplethysmography (PPG) uses light to detect volumetric changes in blood, and is integrated into many healthcare devices to monitor various physiological measurements. However, an unresolved limitation of PPG is the effect of skin pigmentation on the signal and its impact on PPG based applications such as pulse oximetry. Hence, an in-silico model of the human finger was developed using the Monte Carlo (MC) technique to simulate light interactions with different melanin concentrations in a human finger, as it is the primary determinant of skin pigmentation. The AC/DC ratio in reflectance PPG mode was evaluated at source-detector separations of 1 mm and 3 mm as the convergence rate (Q), a parameter that quantifies the accuracy of the simulation, exceeded a threshold of 0.001. At a source-detector separation of 3 mm, the AC/DC ratio of light skin was 0.472 times more than moderate skin and 6.39 than dark skin at 660 nm, and 0.114 and 0.141 respectively at 940 nm. These findings are significant for the development of PPG-based sensors given the ongoing concerns regarding the impact of skin pigmentation on healthcare devices.


Assuntos
Melaninas , Fotopletismografia , Humanos , Fotopletismografia/métodos , Método de Monte Carlo , Oximetria/métodos , Dedos/fisiologia
2.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475146

RESUMO

Various sensing modalities, including external and internal sensors, have been employed in research on human activity recognition (HAR). Among these, internal sensors, particularly wearable technologies, hold significant promise due to their lightweight nature and simplicity. Recently, HAR techniques leveraging wearable biometric signals, such as electrocardiography (ECG) and photoplethysmography (PPG), have been proposed using publicly available datasets. However, to facilitate broader practical applications, a more extensive analysis based on larger databases with cross-subject validation is required. In pursuit of this objective, we initially gathered PPG signals from 40 participants engaged in five common daily activities. Subsequently, we evaluated the feasibility of classifying these activities using deep learning architecture. The model's performance was assessed in terms of accuracy, precision, recall, and F-1 measure via cross-subject cross-validation (CV). The proposed method successfully distinguished the five activities considered, with an average test accuracy of 95.14%. Furthermore, we recommend an optimal window size based on a comprehensive evaluation of performance relative to the input signal length. These findings confirm the potential for practical HAR applications based on PPG and indicate its prospective extension to various domains, such as healthcare or fitness applications, by concurrently analyzing behavioral and health data through a single biometric signal.


Assuntos
Redes Neurais de Computação , Fotopletismografia , Humanos , Fotopletismografia/métodos , Estudos Prospectivos , Eletrocardiografia/métodos , Atividades Humanas
3.
Physiol Meas ; 45(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38478997

RESUMO

Objective.Photoplethysmography is a non-invasive optical technique that measures changes in blood volume within tissues. It is commonly and being increasingly used for a variety of research and clinical applications to assess vascular dynamics and physiological parameters. Yet, contrary to heart rate variability measures, a field which has seen the development of stable standards and advanced toolboxes and software, no such standards and limited open tools exist for continuous photoplethysmogram (PPG) analysis. Consequently, the primary objective of this research was to identify, standardize, implement and validate key digital PPG biomarkers.Approach.This work describes the creation of a standard Python toolbox, denotedpyPPG, for long-term continuous PPG time-series analysis and demonstrates the detection and computation of a high number of fiducial points and digital biomarkers using a standard fingerbased transmission pulse oximeter.Main results.The improved PPG peak detector had an F1-score of 88.19% for the state-of-the-art benchmark when evaluated on 2054 adult polysomnography recordings totaling over 91 million reference beats. The algorithm outperformed the open-source original Matlab implementation by ∼5% when benchmarked on a subset of 100 randomly selected MESA recordings. More than 3000 fiducial points were manually annotated by two annotators in order to validate the fiducial points detector. The detector consistently demonstrated high performance, with a mean absolute error of less than 10 ms for all fiducial points.Significance.Based on these fiducial points,pyPPGengineered a set of 74 PPG biomarkers. Studying PPG time-series variability usingpyPPGcan enhance our understanding of the manifestations and etiology of diseases. This toolbox can also be used for biomarker engineering in training data-driven models.pyPPGis available onhttps://physiozoo.com/.


Assuntos
Fotopletismografia , Processamento de Sinais Assistido por Computador , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Polissonografia , Algoritmos , Biomarcadores
4.
Physiol Meas ; 45(3)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38430568

RESUMO

Objective. In previous studies, the factors affecting the accuracy of imaging photoplethysmography (iPPG) heart rate (HR) measurement have been focused on the light intensity, facial reflection angle, and motion artifacts. However, the factor of specularly reflected light has not been studied in detail. We explored the effect of specularly reflected light on the accuracy of HR estimation and proposed an estimation method for the direction of specularly radiated light.Approach. To study the HR measurement accuracy influenced by specularly reflected light, we control the component of specularly reflected light by controlling its angle. A total of 100 videos from four different reflected light angles were collected, and 25 subjects participated in the dataset collection. We extracted angles and illuminations for 71 facial regions, fitting sample points through interpolation, and selecting the angle corresponding to the maximum weight in the fitted curve as the estimated reflected angle.Main results. The experimental results show that higher specularly reflected light compromises HR estimation accuracy under the same value of light intensity. Notably, at a 60° angle, the HR accuracy (ACC) increased by 0.7%, while the signal-to-noise ratio and Pearson correlation coefficient increased by 0.8 dB and 0.035, respectively, compared to 0°. The overall root mean squared error, standard deviation, and mean error of our proposed reflected light angle estimation method on the illumination multi-angle incidence (IMAI) dataset are 1.173°, 0.978°, and 0.773°. The average Pearson value is 0.8 in the PURE rotation dataset. In addition, the average ACC of HR measurements in the PURE dataset is improved by 1.73% in our method compared to the state-of-the-art traditional methods.Significance. Our method has great potential for clinical applications, especially in bright light environments such as during surgery, to improve accuracy and monitor blood volume changes in blood vessels.


Assuntos
Fotopletismografia , Processamento de Sinais Assistido por Computador , Humanos , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Rotação , Artefatos , Algoritmos
5.
JACC Clin Electrophysiol ; 10(2): 334-345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38340117

RESUMO

BACKGROUND: Continuous monitoring for atrial fibrillation (AF) using photoplethysmography (PPG) from smartwatches or other wearables is challenging due to periods of poor signal quality during motion or suboptimal wearing. As a result, many consumer wearables sample infrequently and only analyze when the user is at rest, which limits the ability to perform continuous monitoring or to quantify AF. OBJECTIVES: This study aimed to compare 2 methods of continuous monitoring for AF in free-living patients: a well-validated signal processing (SP) heuristic and a convolutional deep neural network (DNN) trained on raw signal. METHODS: We collected 4 weeks of continuous PPG and electrocardiography signals in 204 free-living patients. Both SP and DNN models were developed and validated both on holdout patients and an external validation set. RESULTS: The results show that the SP model demonstrated receiver-operating characteristic area under the curve (AUC) of 0.972 (sensitivity 99.6%, specificity: 94.4%), which was similar to the DNN receiver-operating characteristic AUC of 0.973 (sensitivity 92.2, specificity: 95.5%); however, the DNN classified significantly more data (95% vs 62%), revealing its superior tolerance of tracings prone to motion artifact. Explainability analysis revealed that the DNN automatically suppresses motion artifacts, evaluates irregularity, and learns natural AF interbeat variability. The DNN performed better and analyzed more signal in the external validation cohort using a different population and PPG sensor (AUC, 0.994; 97% analyzed vs AUC, 0.989; 88% analyzed). CONCLUSIONS: DNNs perform at least as well as SP models, classify more data, and thus may be better for continuous PPG monitoring.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Humanos , Fibrilação Atrial/diagnóstico , Fotopletismografia/métodos , Heurística , Monitorização Fisiológica
6.
PLoS One ; 19(2): e0298354, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38363753

RESUMO

The pulse arrival time (PAT) has been considered a surrogate measure for pulse wave velocity (PWV), although some studies have noted that this parameter is not accurate enough. Moreover, the inter-beat interval (IBI) time series obtained from successive pulse wave arrivals can be employed as a surrogate measure of the RR time series avoiding the use of electrocardiogram (ECG) signals. Pulse arrival detection is a procedure needed for both PAT and IBI measurements and depends on the proper fiducial points chosen. In this paper, a new set of fiducial points that can be tailored using several optimization criteria is proposed to improve the detection of successive pulse arrivals. This set is based on the location of local maxima and minima in the systolic rise of the pulse wave after fractional differintegration of the signal. Several optimization criteria have been proposed and applied to high-quality recordings of a database with subjects who were breathing at different rates while sitting or standing. When a proper fractional differintegration order is selected by using the RR time series as a reference, the agreement between the obtained IBI and RR is better than that for other state-of-the-art fiducial points. This work tested seven different traditional fiducial points. For the agreement analysis, the median standard deviation of the difference between the IBI and RR time series is 5.72 ms for the proposed fiducial point versus 6.20 ms for the best-performing traditional fiducial point, although it can reach as high as 9.93 ms for another traditional fiducial point. Other optimization criteria aim to reduce the standard deviation of the PAT (7.21 ms using the proposed fiducial point versus 8.22 ms to 15.4 ms for the best- and worst-performing traditional fiducial points) or to minimize the standard deviation of the PAT attributable to breathing (3.44 ms using the proposed fiducial point versus 4.40 ms to 5.12 ms for best- and worst-performing traditional fiducial points). The use of these fiducial points may help to better quantify the beat-to-beat PAT variability and IBI time series.


Assuntos
Fotopletismografia , Análise de Onda de Pulso , Humanos , Fotopletismografia/métodos , Análise de Onda de Pulso/métodos , Frequência Cardíaca , Fatores de Tempo , Eletrocardiografia
7.
Pacing Clin Electrophysiol ; 47(4): 511-517, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38407298

RESUMO

BACKGROUND: Wearable devices based on the PPG algorithm can detect atrial fibrillation (AF) effectively. However, further investigation of its application on long-term, continuous monitoring of AF burden is warranted. METHOD: The performance of a smartwatch with continuous photoplethysmography (PPG) and PPG-based algorithms for AF burden estimation was evaluated in a prospective study enrolling AF patients admitted to Beijing Anzhen Hospital for catheter ablation from September to November 2022. A continuous Electrocardiograph patch (ECG) was used as the reference device to validate algorithm performance for AF detection in 30-s intervals. RESULTS: A total of 578669 non-overlapping 30-s intervals for PPG and ECG each from 245 eligible patients were generated. An interval-level sensitivity of PPG was 96.3% (95% CI 96.2%-96.4%), and specificity was 99.5% (95% CI 99.5%-99.6%) for the estimation of AF burden. AF burden estimation by PPG was highly correlated with AF burden calculated by ECG via Pearson correlation coefficient (R2 = 0.996) with a mean difference of -0.59 (95% limits of agreement, -7.9% to 6.7%). The subgroup study showed the robust performance of the algorithm in different subgroups, including heart rate and different hours of the day. CONCLUSION: Our results showed the smartwatch with an algorithm-based PPG monitor has good accuracy and stability in continuously monitoring AF burden compared with ECG patch monitors, indicating its potential for diagnosing and managing AF.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fotopletismografia/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Algoritmos , Eletrocardiografia/métodos
8.
BMC Med Inform Decis Mak ; 24(1): 50, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355559

RESUMO

BACKGROUND: This study was conducted to address the existing drawbacks of inconvenience and high costs associated with sleep monitoring. In this research, we performed sleep staging using continuous photoplethysmography (PPG) signals for sleep monitoring with wearable devices. Furthermore, our aim was to develop a more efficient sleep monitoring method by considering both the interpretability and uncertainty of the model's prediction results, with the goal of providing support to medical professionals in their decision-making process. METHOD: The developed 4-class sleep staging model based on continuous PPG data incorporates several key components: a local attention module, an InceptionTime module, a time-distributed dense layer, a temporal convolutional network (TCN), and a 1D convolutional network (CNN). This model prioritizes both interpretability and uncertainty estimation in its prediction results. The local attention module is introduced to provide insights into the impact of each epoch within the continuous PPG data. It achieves this by leveraging the TCN structure. To quantify the uncertainty of prediction results and facilitate selective predictions, an energy score estimation is employed. By enhancing both the performance and interpretability of the model and taking into consideration the reliability of its predictions, we developed the InsightSleepNet for accurate sleep staging. RESULT: InsightSleepNet was evaluated using three distinct datasets: MESA, CFS, and CAP. Initially, we assessed the model's classification performance both before and after applying an energy score threshold. We observed a significant improvement in the model's performance with the implementation of the energy score threshold. On the MESA dataset, prior to applying the energy score threshold, the accuracy was 84.2% with a Cohen's kappa of 0.742 and weighted F1 score of 0.842. After implementing the energy score threshold, the accuracy increased to a range of 84.8-86.1%, Cohen's kappa values ranged from 0.75 to 0.78 and weighted F1 scores ranged from 0.848 to 0.861. In the case of the CFS dataset, we also noted enhanced performance. Before the application of the energy score threshold, the accuracy stood at 80.6% with a Cohen's kappa of 0.72 and weighted F1 score of 0.808. After thresholding, the accuracy improved to a range of 81.9-85.6%, Cohen's kappa values ranged from 0.74 to 0.79 and weighted F1 scores ranged from 0.821 to 0.857. Similarly, on the CAP dataset, the initial accuracy was 80.6%, accompanied by a Cohen's kappa of 0.73 and weighted F1 score was 0.805. Following the application of the threshold, the accuracy increased to a range of 81.4-84.3%, Cohen's kappa values ranged from 0.74 to 0.79 and weighted F1 scores ranged from 0.813 to 0.842. Additionally, by interpreting the model's predictions, we obtained results indicating a correlation between the peak of the PPG signal and sleep stage classification. CONCLUSION: InsightSleepNet is a 4-class sleep staging model that utilizes continuous PPG data, serves the purpose of continuous sleep monitoring with wearable devices. Beyond its primary function, it might facilitate in-depth sleep analysis by medical professionals and empower them with interpretability for intervention-based predictions. This capability can also support well-informed clinical decision-making, providing valuable insights and serving as a reliable second opinion in medical settings.


Assuntos
Aprendizado Profundo , Humanos , Incerteza , Fotopletismografia/métodos , Reprodutibilidade dos Testes , Sono
9.
Physiol Meas ; 45(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38387047

RESUMO

Objective.Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz.Approach.The method applies template matching to leverage the random nature of sampling time and expected change in the PAT.Main results.The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively.Significance.This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.


Assuntos
Determinação da Pressão Arterial , Dispositivos Eletrônicos Vestíveis , Humanos , Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Frequência Cardíaca , Fotopletismografia/métodos
10.
Physiol Meas ; 45(3)2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38387061

RESUMO

Objective. Although inter-beat intervals (IBI) and the derived heart rate variability (HRV) can be acquired through consumer-grade photoplethysmography (PPG) wristbands and have been applied in a variety of physiological and psychophysiological conditions, their accuracy is still unsatisfactory.Approach.In this study, 30 healthy participants concurrently wore two wristbands (E4 and Honor 5) and a gold-standard electrocardiogram (ECG) device under four conditions: resting, deep breathing with a frequency of 0.17 Hz and 0.1 Hz, and mental stress tasks. To quantitatively validate the accuracy of IBI acquired from PPG wristbands, this study proposed to apply an information-based similarity (IBS) approach to quantify the pattern similarity of the underlying dynamical temporal structures embedded in IBI time series simultaneously recorded using PPG wristbands and the ECG system. The occurrence frequency of basic patterns and their rankings were analyzed to calculate the IBS distance from gold-standard IBI, and to further calculate the signal-to-noise ratio (SNR) of the wristband IBI time series.Main results.The accuracies of both HRV and mental state classification were not satisfactory due to the low SNR in the wristband IBI. However, by rejecting data segments of SNR < 25, the Pearson correlation coefficients between the wristbands' HRV and the gold-standard HRV were increased from 0.542 ± 0.235 to 0.922 ± 0.120 for E4 and from 0.596 ± 0.227 to 0.859 ± 0.145 for Honor 5. The average accuracy of four-class mental state classification increased from 77.3% to 81.9% for E4 and from 79.3% to 83.3% for Honor 5.Significance.Consumer-grade PPG wristbands are acceptable for HR and HRV monitoring when removing low SNR segments. The proposed method can be applied for quantifying the accuracies of IBI and HRV indices acquired via any non-ECG system.


Assuntos
Determinação da Frequência Cardíaca , Fotopletismografia , Humanos , Fotopletismografia/métodos , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Eletrocardiografia/métodos
11.
Opt Express ; 32(3): 4446-4456, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38297646

RESUMO

Commercial photoplethysmography (PPG) sensors rely on the measurement of continuous-wave diffuse reflection signals (CW-DRS) to monitor heart rate. Using Monte Carlo modeling of light propagation in skin, we quantitatively evaluate the dependence of continuous-wave photoplethysmography (CW-PPG) in commercial wearables on source-detector distance (SDD). Specifically, when SDD increases from 0.5 mm to 3.3 mm, CW-PPG signal increases by roughly 846% for non-obese (NOB) skin and roughly 683% for morbidly obese (MOB) skin. Ultimately, we introduce the concept of time-of-flight PPG (TOF-PPG) which can significantly improve heart rate signals. Our model shows that the optimized TOF-PPG improves heart rate monitoring experiences by roughly 47.9% in NOB and 93.2% in MOB when SDD = 3.3 mm is at green light. Moving forward, these results will provide a valuable source for hypothesis generation in the scientific community to improve heart rate monitoring.


Assuntos
Determinação da Frequência Cardíaca , Obesidade Mórbida , Humanos , Fotopletismografia/métodos , Monitorização Fisiológica , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador
12.
J Exp Biol ; 227(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38284767

RESUMO

Heart rate is a crucial physiological indicator for fish, but current measurement methods are often invasive or require delicate manipulation. In this study, we introduced two non-invasive and easy-to-operate methods based on photoplethysmography, namely reflectance-type photoplethysmography (PPG) and remote photoplethysmography (rPPG), which we applied to the large yellow croaker (Larimichthys crocea). PPG showed perfect synchronization with electrocardiogram (ECG), with a Pearson's correlation coefficient of 0.99999. For rPPG, the results showed good agreement with ECG. Under active provision of green light, the Pearson's correlation coefficient was 0.966, surpassing the value of 0.947 under natural light. Additionally, the root mean square error was 0.810, which was lower than the value of 1.30 under natural light, indicating not only that the rPPG method had relatively high accuracy but also that green light may have the potential to further improve its accuracy.


Assuntos
Eletrocardiografia , Fotopletismografia , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
13.
Physiol Meas ; 45(2)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38266291

RESUMO

Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.


Assuntos
Fibrilação Atrial , Taquicardia Ventricular , Humanos , Frequência Cardíaca , Fibrilação Atrial/diagnóstico , Fotopletismografia/métodos , Benchmarking , Taquicardia Ventricular/diagnóstico , Algoritmos , Eletrocardiografia/métodos
14.
Physiol Meas ; 45(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38176078

RESUMO

Smoking is widely recognized as a significant risk factor in the progression of arterial stiffness and cardiovascular diseases. Valuable information related to cardiac arrhythmias and heart function can be obtained by analyzing biosignals such as the electrocardiogram (ECG) and the photoplethysmogram (PPG). The PPG signal is a non-invasive optical technique that can be used to evaluate the changes in blood volume, and thus it can be linked to the health of the vascular system.Objective. In this study, the impact of three smoking habits-cigarettes, shisha, and electronic cigarettes (e-cigarettes)-on the features of the PPG signal were investigated.Approach. The PPG signals are measured for 45 healthy smokers before, during, and after the smoking session and then processed to extract the morphological features. Quantitative statistical techniques were used to analyze the PPG features and provide the most significant features of the three smoking habits. The impact of smoking is observed through significant changes in the features of the PPG signal, indicating blood volume instability.Main results. The results revealed that the three smoking habits influence the characteristics of the PPG signal significantly, which presentseven after 15 min of smoking. Among them, shisha has the greatest impact on PPG features, particularly on heart rate, systolic time, augmentation index, and peak pulse interval change. In contrast, e-cigarettes have the least effect on PPG features. Interestingly, smoking electronic cigarettes, which many participants use as a substitute for traditional cigarettes when attempting to quit smoking, has nearly a comparable effect to regular smoking.Significance. The findings suggest that individuals who smoke shisha are more likely to develop cardiovascular diseases at an earlier age compared to those who have other smoking habits. Understanding the variations in the PPG signal caused by smoking can aid in the early detection of cardiovascular disorders and provide insight into cardiac conditions. This ultimately contributes to the prevention of the development of cardiovascular diseases and the development of a health screening system.


Assuntos
Doenças Cardiovasculares , Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Fotopletismografia/métodos , Fumar/efeitos adversos , Frequência Cardíaca , Processamento de Sinais Assistido por Computador
15.
Blood Press ; 33(1): 2304190, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38245864

RESUMO

Background: Cuffless blood pressure measurement technologies have attracted significant attention for their potential to transform cardiovascular monitoring.Methods: This updated narrative review thoroughly examines the challenges, opportunities, and limitations associated with the implementation of cuffless blood pressure monitoring systems.Results: Diverse technologies, including photoplethysmography, tonometry, and ECG analysis, enable cuffless blood pressure measurement and are integrated into devices like smartphones and smartwatches. Signal processing emerges as a critical aspect, dictating the accuracy and reliability of readings. Despite its potential, the integration of cuffless technologies into clinical practice faces obstacles, including the need to address concerns related to accuracy, calibration, and standardization across diverse devices and patient populations. The development of robust algorithms to mitigate artifacts and environmental disturbances is essential for extracting clear physiological signals. Based on extensive research, this review emphasizes the necessity for standardized protocols, validation studies, and regulatory frameworks to ensure the reliability and safety of cuffless blood pressure monitoring devices and their implementation in mainstream medical practice. Interdisciplinary collaborations between engineers, clinicians, and regulatory bodies are crucial to address technical, clinical, and regulatory complexities during implementation. In conclusion, while cuffless blood pressure monitoring holds immense potential to transform cardiovascular care. The resolution of existing challenges and the establishment of rigorous standards are imperative for its seamless incorporation into routine clinical practice.Conclusion: The emergence of these new technologies shifts the paradigm of cardiovascular health management, presenting a new possibility for non-invasive continuous and dynamic monitoring. The concept of cuffless blood pressure measurement is viable and more finely tuned devices are expected to enter the market, which could redefine our understanding of blood pressure and hypertension.


This review explores cuffless blood pressure technologies and their impact on clinical practice, highlighting innovative devices that offer non-invasive, continuous and non-continuous monitoring without a cuff. Signal processing is essential for ensuring accurate readings, as it filters out unwanted artifacts and environmental disturbances which could make the reading inaccurate. While these advancements show great potential for transforming cardiovascular care, there are still several challenges to overcome, including the need for standardized protocols and validation studies to ensure their reliability and safety in clinical settings. Collaborative efforts between engineers, clinicians, and regulatory bodies are needed to address the technical and regulatory complexities surrounding the implementation of these technologies. These cuffless blood pressure measurement devices have the potential to reshape how we understand and manage blood pressure and hypertension.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Reprodutibilidade dos Testes , Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Fotopletismografia/métodos
16.
IEEE J Biomed Health Inform ; 28(2): 621-632, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37037253

RESUMO

Remote photoplethysmography (rPPG) has been used to measure vital signs such as heart rate, heart rate variability, blood pressure (BP), and blood oxygen. Recent studies adopt features developed with photoplethysmography (PPG) to achieve contactless BP measurement via rPPG. These features can be classified into two groups: time or phase differences from multiple signals, or waveform feature analysis from a single signal. Here we devise a solution to extract the time difference information from the rPPG signal captured at 30 FPS. We also propose a deep learning model architecture to estimate BP from the extracted features. To prevent overfitting and compensate for the lack of data, we leverage a multi-model design and generate synthetic data. We also use subject information related to BP to assist in model learning. For real-world usage, the subject information is replaced with values estimated from face images, with performance that is still better than the state-of-the-art. To our best knowledge, the improvements can be achieved because of: 1) the model selection with estimated subject information, 2) replacing the estimated subject information with the real one, 3) the InfoGAN assistance training (synthetic data generation), and 4) the time difference features as model input. To evaluate the performance of the proposed method, we conduct a series of experiments, including dynamic BP measurement for many single subjects and nighttime BP measurement with infrared lighting. Our approach reduces the MAE from 15.49 to 8.78 mmHg for systolic blood pressure (SBP) and 10.56 to 6.16 mmHg for diastolic blood pressure(DBP) on a self-constructed rPPG dataset. On the Taipei Veterans General Hospital(TVGH) dataset for nighttime applications, the MAE is reduced from 21.58 to 11.12 mmHg for SBP and 9.74 to 7.59 mmHg for DBP, with improvement ratios of 48.47% and 22.07% respectively.


Assuntos
Determinação da Pressão Arterial , Fotopletismografia , Humanos , Pressão Sanguínea , Fotopletismografia/métodos , Determinação da Pressão Arterial/métodos , Frequência Cardíaca , Raios Infravermelhos
17.
IEEE Rev Biomed Eng ; 17: 180-196, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37186539

RESUMO

Heart rate variability (HRV) is an important metric with a variety of applications in clinical situations such as cardiovascular diseases, diabetes mellitus, and mental health. HRV data can be potentially obtained from electrocardiography and photoplethysmography signals, then computational techniques such as signal filtering and data segmentation are used to process the sampled data for calculating HRV measures. However, uncertainties arising from data acquisition, computational models, and physiological factors can lead to degraded signal quality and affect HRV analysis. Therefore, it is crucial to address these uncertainties and develop advanced models for HRV analysis. Although several reviews of HRV analysis exist, they primarily focus on clinical applications, trends in HRV methods, or specific aspects of uncertainties such as measurement noise. This paper provides a comprehensive review of uncertainties in HRV analysis, quantifies their impacts, and outlines potential solutions. To the best of our knowledge, this is the first study that presents a holistic review of uncertainties in HRV methods and quantifies their impacts on HRV measures from an engineer's perspective. This review is essential for developing robust and reliable models, and could serve as a valuable future reference in the field, particularly for dealing with uncertainties in HRV analysis.


Assuntos
Doenças Cardiovasculares , Eletrocardiografia , Humanos , Frequência Cardíaca/fisiologia , Eletrocardiografia/métodos , Fotopletismografia/métodos
18.
Comput Biol Med ; 168: 107795, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38056206

RESUMO

BACKGROUND: Physiological parameter monitoring based on photoplethysmography (PPG) detection has the advantage of fast, portable, and non-invasive. Changes in the morphology of the PPG waveform can reflect the effect of arterial elasticity changes on blood pressure (BP). However, machine learning models and non-recurrent neural network models typically ignore the time-dependency of continuous PPG data, leading to the decrease of accuracy or the increased calibration frequency. OBJECTIVE: This paper proposes a BiGRU model with attention to estimate BP trends, which uses a single-channel PPG signal combined with demographic information to estimate continuous BP trends point-by-point and to discuss the impact of calibration cycle. METHODS: This paper selects 15 typical subjects from two groups with/without cardiovascular disease (CVD) and evaluates the model performance. Regarding the calibration frequency problem, we set two modes of non-calibration and calibration to validate the results of blood pressure trends estimation. RESULTS: In the calibration mode, the estimation errors (ME ± STD) of SBP for CVD/non-CVD groups are 0.91 ± 10.58 mmHg/0.17 ± 10.06 mmHg respectively, and DBP are 0.34 ± 5.28 mmHg/-0.19 ± 5.36 mmHg; in the non-calibration mode, the estimation errors of SBP for CVD/non-CVD groups are 0.27 ± 9.87 mmHg/-0.82 ± 9.92 mmHg respectively, and DBP are -0.63 ± 3.28 mmHg/0.80 ± 4.93 mmHg. CONCLUSIONS: The results show that the proposed model has high accuracy in estimating BP levels, which is expected to achieve real-time, long-term continuous BP trends monitoring in wearable devices.


Assuntos
Determinação da Pressão Arterial , Doenças Cardiovasculares , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Fotopletismografia/métodos , Análise de Onda de Pulso
19.
IEEE J Biomed Health Inform ; 28(2): 1078-1088, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37948137

RESUMO

OBJECTIVE: The proliferation of wearable devices has escalated the standards for photoplethysmography (PPG) signal quality. This study introduces a lightweight model to address the imperative need for precise, real-time evaluation of PPG signal quality, followed by its deployment and validation utilizing our integrated upper computer and hardware system. METHODS: Multiscale Markov Transition Fields (MMTF) are employed to enrich the morphological information of the signals, serving as the input for our proposed hybrid model (HM). HM undergoes initial pre-training utilizing the MIMIC-III and UCI databases, followed by fine-tuning the Queensland dataset. Knowledge distillation (KD) then transfers the large-parameter model's knowledge to the lightweight hybrid model (LHM). LHM is subsequently deployed on the upper computer for real-time signal quality assessment. RESULTS: HM achieves impressive accuracies of 99.1% and 96.0% for binary and ternary classification, surpassing current state-of-the-art methods. LHM, with only 0.2 M parameters (0.44% of HM), maintains high accuracy despite a 2.6% drop. It achieves an inference speed of 0.023 s per image, meeting real-time display requirements. Furthermore, LHM attains a 97.7% accuracy on a self-created database. HM outperforms current methods in PPG signal quality accuracy, demonstrating the effectiveness of our approach. Additionally, LHM substantially reduces parameter count while maintaining high accuracy, enhancing efficiency and practicality for real-time applications. CONCLUSION: The proposed methodology demonstrates the capability to achieve high-precision and real-time assessment of PPG signal quality, and its practical validation has been successfully conducted during deployment. SIGNIFICANCE: This study contributes a convenient and accurate solution for the real-time evaluation of PPG signals, offering extensive application potential.


Assuntos
Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Algoritmos , Fotopletismografia/métodos , Frequência Cardíaca , Artefatos
20.
J Biophotonics ; 17(1): e202300286, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37614208

RESUMO

This article aims to predict vital signs like heart rate (HR), respiration rate, and arterial oxygen saturation using ambient light video, eliminating chronic distortions through improved frame quality with BER estimation. The study employs the cascade residual CNN-FPNR technique for preprocessing and SNR enhancement using energy variance maximization. The image cascade network (ICNet) facilitates segmentation, achieving strong segmentation in low-light ambient videos. Remote photoplethysmography (iPPG) enables noncontact vital sign monitoring, predicting HR and respiratory rate (RR). An innovative noninvasive temperature and cyclical algorithm, incorporating principal component analysis and fast Fourier transform, evaluate patient HR and RR. To address challenges related to involuntary movements, a dynamic time-warping-based optimization method is used for precise region selection. The study introduces an intensity variance-based threshold analysis for arterial oxygen saturation level determination. Ultimately, the support vector machine (SVM) classification technique evaluates the ground truth, showcasing the system's promising potential for remote and accurate vital sign assessment.


Assuntos
Fotopletismografia , Processamento de Sinais Assistido por Computador , Humanos , Monitorização Fisiológica , Fotopletismografia/métodos , Sinais Vitais , Frequência Cardíaca/fisiologia , Algoritmos